Driver Squib Terminal Shorted to Ground (Active)
SYMPTOMDRIVER SQUIB TERMINAL SHORTED TO GROUND (ACTIVE)
WHEN MONITORED
Continuously with ignition ON.
SET CONDITION
With voltage and current ON, the driver airbag line 1 or line 2 circuit(s) is other than expected.
POSSIBLE CAUSES
- Driver airbag line 1 or line 2 shorted to ground
- Clockspring shorted to ground
- Driver airbag module internal shorted to ground
- ACM defective, driver airbag terminal shorted to ground