Loss of Ignition Run Only (Stored)
SYMPTOMLOSS OF IGNITION RUN ONLY (STORED)
TEST NOTE
This symptom is diagnosed using the test DRIVER SQUIB CIRCUIT OPEN (STORED).
WHEN MONITORED
Continuously with ignition ON.
SET CONDITION
The "Loss of Ignition Run Only" code will set if the voltage on the Fused Ignition Switch Output Run Only circuit falls below 6.0 volts.
POSSIBLE CAUSES
- Stored code has become active
- Stored code has not been reproduced