Operation CHARM: Car repair manuals for everyone.

P0352 Ignition Coil # 2 Primary Circuit

SYMPTOM
P-0352 IGNITION COIL #2 PRIMARY CIRCUIT

WHEN MONITORED
With battery voltage greater than 8 volts during engine cranking or greater than 12 volts with engine running, and none of the coils in dwell when checked.

SET CONDITION
Peak current is not achieved with 2.5 ms of dwell. It takes 3 seconds during cranking or up to 6 seconds while running to set.

POSSIBLE CAUSES
- Auto shutdown output circuit open
- Ignition coil #2 connector terminal observable def
- Ignition coil #2 driver circuit open
- Ignition coil #2 driver circuit shorted to ground
- Ignition coil circuit wiring harness intermittent defect
- Ignition coil circuit wiring harness observed defect
- Ignition coil #2 defective
- PCM defective (ign coil #2)