P0443 EVAP Purge Solenoid Circuit
SYMPTOMP-0443 EVAP PURGE SOLENOID CIRCUIT
WHEN MONITORED
With the ignition key on and the engine running.
SET CONDITION
After arming conditions are satisfied: not powering down, not already in limp-in, time since last solenoid activation> 72 micro seconds. The PCM will set a trouble code if the actual sate of the solenoid does not match the intended state.
POSSIBLE CAUSES
- No possible causes remaining
- Fused ignition switch output circuit open
- Evap purge solenoid defective
- Proportional purge solenoid defective
- Evap purge sol ckt wiring harness intermittent def
- Evap purge solenoid ckt wiring harness obs defect
- Evap purge solenoid control circuit open
- Evap purge solenoid control circuit short to gnd
- Proportional purge sol control ckt short to ground
- Proportional purge solenoid control circuit open
- PWM purge sense circuit open
- PWM purge sense circuit short to ground
- Powertrain control module defective
- Evap purge sol ckt wiring harness intermittent defect
- Evap purge solenoid circuit wiring harness observable defect
- No possible causes remaining