Driver Squib Circuit Open (Stored)
Test 6:
SYMPTOM
DRIVER SQUIB CIRCUIT OPEN (STORED)
WHEN MONITORED
Continuously with ignition ON
SET CONDITION
The ACM has detected an open or high resistance in the Driver Squib Circuits.
POSSIBLE CAUSES
- Driver airbag connector disconnected
- Driver airbag line 1 shorted to driver airbag line 2
- Clockspring shorted
- Driver airbag module shorted
- ACM defective, driver airbag circuit shorted