Driver Squib Circuit Shorted (Active)
Tests 7 - 9:
Tests 10 - 11:
SYMPTOM
DRIVER SQUIB CIRCUIT SHORTED (ACTIVE)
WHEN MONITORED
Continuously with ignition ON.
SET CONDITION
The ACM has detected low resistance in the Driver Squib Circuits.
POSSIBLE CAUSES
- Driver airbag connector disconnected
- Driver airbag line 1 shorted to driver airbag line 2
- Clockspring shorted
- Driver airbag module shorted
- ACM defective, driver airbag circuit shorted