Passenger Squib Terminal Shorted to Battery (Active)
Tests 35 - 36:
SYMPTOM
PASSENGER SQUIB TERMINAL SHORTED TO BATTERY (ACTIVE)
WHEN MONITORED
Continuously with ignition ON.
SET CONDITION
With voltage and current ON, the passenger airbag line 1 or line 2 circuit(s) is other than expected.
POSSIBLE CAUSES
- Passenger airbag line 1 or line 2 shorted to voltage
- ACM defective, passenger airbag shorted to voltage