Operation CHARM: Car repair manuals for everyone.

Passenger Squib Terminal Shorted to Ground (Active)

Tests 37 - 39:




SYMPTOM
PASSENGER SQUIB TERMINAL SHORTED TO GROUND (ACTIVE)

WHEN MONITORED
Continuously with ignition ON.

SET CONDITION
With voltage and current ON, the passenger airbag line 1 or line 2 circuit(s) is other than expected.

POSSIBLE CAUSES
- Passenger airbag line 1 or line 2 shorted to ground
- Passenger airbag module shorted to ground
- ACM defective, passenger airbag shorted to ground