Either Squib Terminal Shorted to Battery (Active)
Tests 18 - 19:
Test 20:
SYMPTOM
EITHER SQUIB TERMINAL SHORTED TO BATTERY (ACTIVE)
WHEN MONITORED
Continuously with the ignition ON.
SET CONDITON
With ignition ON, the driver airbag line 1 or line 2 circuit value is other than expected.
POSSIBLE CAUSES
- PAB line 1 or 2 short to voltage
- Clockspring defective, short to voltage
- Driver airbag line 1 or line 2 short to voltage
- ACM defective, DAB or PAB short to voltage