Operation CHARM: Car repair manuals for everyone.

Fuel Delivery and Air Induction

OPERATION
U.S. REQUIREMENTS Use only natural gas which meets the requirements for gas quality as out- lined in the National Fire Protection Association (NFPA) 52 and the American National Standard ANSI/AGA NGV2. Use of natural gas that does not meet the above requirements may result in starting and derivability problems and damage to critical fuel system components.

CANADIAN REQUIREMENTS Use only natural gas which meets the requirements for gas quality as specified in Canadian Standards Association (CSA) B51- 97, Part 2, Section 405 G4.1.2 or SAE J1616. Use of natural gas that does not meet these requirements may result in starting and derivability problems and damage to critical fuel system components.

FUEL SYSTEM CAPACITY
- Total water volume of 4 fuel cylinders: 220.5 L (58.2 U.S. gallons equivalent).

FUEL SYSTEM PRESSURE
- Maximum fuel cylinder pressure: 3600 PSI AT 38 °C (70 °F).
- Test pressure at fuel rail: 110 PSI min.-125 PSI max.