Passenger Squib Circuit Shorted to Ground (Active)
Test 1:
Test 2 - 4:
Test 5 - 7:
SYMPTOM
PASSENGER SQUIB CKT SHORT TO GND (ACTIVE)
WHEN MONITORED
Continuously with the ignition ON.
SET CONDITION
With the voltage ON, the passenger airbag line 1 or line 2 circuit(s) is other than expected.
POSSIBLE CAUSES
- Active code present only with PAB ON/OFF SW OFF
- PAB/PAD switch line 1 or line 2 shorted to ground
- Passenger airbag line 1 or line 2 shorted to ground
- ACM defective, line 1/ line 2 short to ground
- Passenger airbag module shorted to ground
- PAB ON/OFF switch - passenger squib not shorted
- Passenger airbag ON/OFF switch short to GND