Driver Squib Shorted to Ground (Active)
Test 1:
Test 2 - 3:
Test 4 - 5:
SYMPTOM
DRIVER SQUIB SHORT TO GROUND (ACTIVE)
WHEN MONITORED
When the ignition is ON, the ACM monitors the voltage of the Driver Squib circuits.
SET CONDITION
The ACM has detected a short to ground in the Driver Squib circuits.
POSSIBLE CAUSES
- Driver Airbag Module short to ground
- Clockspring DAB circuits short to ground
- Driver Airbag line 2 shorted to ground
- Driver Airbag line 1 shorted to ground
- ACM, Driver Airbag short to ground