Manifold Pressure/Vacuum Sensor: Service and Repair
REMOVAL1. Disconnect the negative battery cable.
Fig. 16 MAP Sensor:
2. Remove vacuum hose and mounting screws from manifold absolute pressure (MAP) sensor.
3. Disconnect electrical connector from sensor. Remove sensor.
INSTALLATION
1. Install sensor.
2. Install screws and tighten to PLASTIC MANIFOLD 1.7 Nm (15 in. lbs.) ALUMINUM MANIFOLD 3.3 Nm (30 in. lbs.).
3. Connect the electrical connector to the sensor. Install vacuum hose.
4. Connect the negative battery cable.