Starter Motor
Manufacturer MitsubishiPower Rating 1.2 kilowatt (1.6 Horsepower)
Voltage 12 Volts
Free Running Test Voltage 11.2 Volts
Free Running Test Maximum Amperage Draw 90 Amperes
Free Running Test Minimum Speed 2600 rpm
* Cranking Amperage Draw Test 130 Amperes
* Test at operating temperature. Cold engine, tight (new) engine, or heavy oil will increase starter amperage draw.