Evaporator Temperature Sensor Circuit Open (Active)
Tests 1 - 2:
Tests 3 - 4:
SYMPTOM
EVAPORATOR TEMPERATURE SENSOR CIRCUIT OPEN (ACTIVE)
WHEN MONITORED
With the ignition ON.
SET CONDITION
This DTC Will set if the A/C-Heater Control Module sees voltage above 4.9 volts on the Evaporator Temperature Sensor Signal circuit.
POSSIBLE CAUSES
- Evaporator temperature sensor signal circuit shorted high
- Evaporator temperature sensor
- Evaporator temperature sensor signal circuit open
- Sensor ground circuit open
- A/C-Heater control module