All Doors Fail to Lock & Unlock From One Switch
Test 1 - 3:
Test 4 - 9:
Test 10 - 14:
SYMPTOM
ALL DOORS FAIL TO LOCK & UNLOCK FROM ONE SWITCH
POSSIBLE CAUSES
- Driver door switch ground circuit open
- Passenger door switch ground circuit open
- Cylinder lock switch ground circuit open
- Central timer module - Passenger door switch MUX open
- Cylinder lock switch MUX circuit open
- Driver door switch MUX circuit open
- Passenger door switch MUX circuit open
- Driver door switch MUX circuit shorted to voltage
- Passenger door switch MUX circuit shorted to voltage
- Driver door lock switch
- Cylinder lock switch - Open
- Central timer module - Driver door switch MUX open
- Passenger door lock switch - Open