Operation CHARM: Car repair manuals for everyone.

P0420

Test 1:




Test 2 - 6:






SYMPTOM
P0420-1/1 CATALYTIC CONVERTER EFFICIENCY

WHEN MONITORED
After engine warm up to 147 °F, 180 seconds of open throttle operation, at a speed greater than 20 mph, with the engine at 1200 - 1700 rpm and MAP vacuum between 15.0 and 21.0 inches of mercury (Hg).

SET CONDITION
As catalyst efficiency deteriorates, the switch rate of the downstream O2 sensor approaches that of the upstream O2 sensor. If at any point during the test the switch ratio reaches a predetermined value a counter is incremented by one.

POSSIBLE CAUSES
- Good trip equal to zero
- Visually inspect catalytic converter
- Exhaust leak
- Engine mechanical problem
- Upstream O2 sensor older than downstream O2 sensor
- Catalytic converter