Operation CHARM: Car repair manuals for everyone.

P1682

Test 1:




Test 2 - 5:




Test 2 -:






SYMPTOM
P1682-CHARGING SYSTEM VOLTAGE TOO LOW

WHEN MONITORED
With the ignition key on and the engine running over 1500 RPM after 25 seconds.

SET CONDITION
When the PCM regulates the generator field and there are no detected field problems, but the voltage output does not increase.

POSSIBLE CAUSES
- Charging voltage below 15.1 volts
- Battery temperature sensor
- Resistance in the battery positive circuit
- (K125) generator field source circuit open
- Resistance in the generator ground
- (K125) generator field source circuit shorted to ground
- (K20) generator field control circuit open
- Resistance in the generator field coil
- PCM