Operation CHARM: Car repair manuals for everyone.

Driver Squib 1 Shorted to Battery

Test 1:




Test 2 - 4:




Test 5 - 6:






SYMPTOM
DRIVER SQUIB 1 SHORT TO BATTERY

WHEN MONITORED
With the ignition on the ACM monitors the voltage of the Driver Squib 1 circuits.

SET CONDITION
The ACM has detected high voltage on the Driver Squib 1 circuits.

POSSIBLE CAUSES
- Driver Airbag Circuit Short To Battery
- Clockspring, Driver Squib 1 Circuit Short To Battery
- Driver Squib 1 Line 1 Or Line 2 Short To Battery
- ACM, Driver Squib 1 Circuits Short To Battery
- Stored Code Or Intermittent Condition
- Active Code Present