Operation CHARM: Car repair manuals for everyone.

Loss of Ignition Run - Start

Test 1 - 2:




Test 2 - 6:




Test 7:






SYMPTOM
LOSS OF IGNITION RUN - START

WHEN MONITORED
With the ignition in the Run or Start position the module monitors the Run - Start circuit for proper system voltage.

SET CONDITION
The code will set, if the voltage on the Run - Start circuit drops below approximately 4.5 volts for the ACM.

POSSIBLE CAUSES
- Airbag System Component Shorted To Ground
- Ignition Switch Run-start Circuit Open
- Fused Ignition Switch Output Run-start Circuit Open
- ACM, Fused Ignition Output Run-start Circuit Open
- Module Run - Start Shorted To Ground
- Stored Code Or Intermittent Condition
- Active Code Present