Loss of Ignition Run - Start
Test 1 - 2:
Test 2 - 6:
Test 7:
SYMPTOM
LOSS OF IGNITION RUN - START
WHEN MONITORED
With the ignition in the Run or Start position the module monitors the Run - Start circuit for proper system voltage.
SET CONDITION
The code will set, if the voltage on the Run - Start circuit drops below approximately 4.5 volts for the ACM.
POSSIBLE CAUSES
- Airbag System Component Shorted To Ground
- Ignition Switch Run-start Circuit Open
- Fused Ignition Switch Output Run-start Circuit Open
- ACM, Fused Ignition Output Run-start Circuit Open
- Module Run - Start Shorted To Ground
- Stored Code Or Intermittent Condition
- Active Code Present