Passenger Squib 1 Shorted to Ground
Test 1:
Test 2 - 4:
Test 5:
SYMPTOM
PASSENGER SQUIB 1 SHORT TO GROUND
WHEN MONITORED
When the ignition is on, the ACM monitors the resistance of the Passenger Squib 1 circuits for low resistance.
SET CONDITION
The ACM has detected a short to ground in the Passenger Squib 1 circuits.
POSSIBLE CAUSES
- Passenger Airbag Circuit Short To Ground
- Passenger Squib 1 Line 1 And Line 2 Short To Ground
- Stored Code Or Intermittent Condition
- ACM, Passenger Squib 1 Circuit Short To Ground
- Active Code Present