Neutral Indicator Open
Test 1 - 2:
Test 3 - 6:
Test 7:
SYMPTOM
NEUTRAL INDICATOR OPEN
WHEN MONITORED
Continuously with the ignition on.
SET CONDITION
The Transfer Case Control Module detects an open in the Neutral Indicator circuit.
POSSIBLE CAUSES
- Intermittent wiring and connectors
- Fused ignition switch output circuit open
- Neutral indicator circuit open
- Neutral indicator circuit short to voltage
- Transfer case selector switch
- Transfer case control module