Driver Door Lock Switch Input Circuit Stuck
Test 1 - 3:
SYMPTOM
DRIVER DOOR LOCK SWITCH INPUT CIRCUIT STUCK
WHEN MONITORED
At all times when battery power is supplied to the Instrument Cluster.
SET CONDITION
When the instrument cluster senses voltage to the driver door lock switch between 1.3 and 3.75 for over 20 seconds, this code will set.
POSSIBLE CAUSES
- DTC present
- Instrument cluster - door lock switch voltage incorrect
- Door lock switch MUX circuit partial short to ground
- Door lock switch stuck