Recirc Circuit Shorted to Ignition or Battery
RECIRC CIRCUIT SHORTED TO IGN OR BATTWHEN MONITORED
When the Actuator Circuit Test is executed.
SET CONDITION
If the A/C Heater Control detects a short to voltage on the (C32) Recirculation Door Driver circuit.
POSSIBLE CAUSES
- Door driver circuit(s) shorted to voltage
- Door driver circuits shorted together
- Door actuator(s)
- A/C Heater control