Horn Fails to Sound When Alarm Is Tripped
HORN FAILS TO SOUND WHEN ALARM IS TRIPPEDPOSSIBLE CAUSES
- DTC present
- Horn circuit
- Instrument cluster
1. HORN RELAY CONTROL CIRCUIT DTC ACTIVE
Turn the ignition on.
With the DRBIII(R), read FCM DTC's.
Q: Does the DRBIII(R) display a HORN RELAY CONTROL CIRCUIT DTC active?
YES: Refer to the Ignition, Power, Accessory category for the related symptom(s). Perform VTSS VERIFICATION TEST - 1A. VTSS Verification Test
NO: Go To 2
2. HORN CIRCUIT DIAGNOSTICS
Q: Does the horn operate from the horn button?
YES: Replace and program the Instrument Cluster. Perform Body Verification Test - Ver 1. Body Verification Test
NO: Refer to symptom Horns Inoperative in the Ignition, Power, Accessory category. Perform VTSS VERIFICATION TEST - 1A. VTSS Verification Test