Rear Blower Motor
REMOVALRear Blower Motor:
1. Remove the rear HVAC housing and place it on a workbench.
2. Disconnect the rear HVAC wire harness connector from the rear blower motor.
3. Remove the three screws that secure the rear blower motor to the rear HVAC housing and remove the blower motor.
INSTALLATION
1. Position the rear blower motor into the rear HVAC housing.
2. Install the three screws that secure the rear blower motor to the rear HVAC housing. Tighten the screws to 2 N.m (17 in. lbs.).
3. Connect the rear HVAC wire harness connector to the rear blower motor.
4. Install the rear HVAC housing.