Upstream 1/1 - 3.3/3.8L
REMOVAL - UPSTREAM 1/1 - 3.3/3.8L
1. Remove battery.
2. Remove the battery tray.
3. Disconnect the speed control vacuum harness from servo.
4. Disconnect the electrical connector from servo.
Figure 1 O2 SENSOR 1/1
5. Remove the speed control servo and bracket and reposition.
6. Use a socket such as the Snap-On(R) YA8875 or equivalent to remove the sensor (Figure 1).
7. When the sensor is removed, the threads must be cleaned with an 18 mm X 1.5 + 6E tap. If using the original sensor, coat the threads with Loctite 771-64 anti-seize compound or equivalent.