Installation
INSTALLATION
1. Position the electrohydraulic unit in the transmission housing.
2. Insert selector valve (1) in driver of detent plate (2). When installing the electrohydraulic control module in the transmission housing, the plastic part of the selector valve (1) must engage in the driver of the detent plate (2).
3. Install the Torx(R) socket bolts (3) and torque to 8 Nm (71 in.lbs.).
4. Install a new oil filter (4).
5. Install oil pan (5) and torque the oil pan bolts to 8 Nm (71 in.lbs.).
6. Install the oil drain plug (8) with a new drain plug gasket (9). Torque the drain plug to 20 Nm (177 in.lbs.).
7. Install the adapter plug (12) into the transmission housing and tighten the bolt (11) to 2.5 Nm (22 in.lbs.).
8. Check O-ring on plug connector (1), and replace if necessary.
9. Install the plug connector (1) into the adapter plug (2). Turn bayonet lock of adapter plug (2) clockwise to connect plug connector (1).
10. Position the heat shield (2) onto the transmission housing and install the screw (1) and bolt (3) to hold the shield in place.
11. Fill the transmission with the correct oil Maintenance A/C Refrigerant Description - Automatic Transmission Fluid - NAG1 Description and Operation Description and Operation Description and Operation HOAT Coolant Description and Operation using the standard procedure Transmission Fill - NAG1.