Operation CHARM: Car repair manuals for everyone.

B2184






B2184-IGNITION UNLOCK/RUN/START CONTROL CIRCUIT LOW





For a complete wiring diagram, refer to the Wiring Information Electrical Diagrams.

Theory of Operation

The family of B2100 Diagnostic Trouble Codes (DTCs) typically describes ignition performance related faults. These are often caused by a contradiction of switch status information. For example, if an Electronic Control Unit (ECU) receives a bussed message indicating ignition switch position but the state of a hardwired ignition circuit indicates another switch position a B2100 series DTC would likely result.

These DTCs can be caused by a number of conditions including:

- loose connections
- missing or blown fuses
- faulty component
- vehicle no start or long crank time

Verify the proper operation of the starting system and verify that this DTC is active before proceeding with the diagnostic test.

- When Monitored:
With the ignition on.

- Set Condition:
The Front Control Module (FCM) will set this if the Left Trailer Tow Brake Lamp Relay Control circuit is shorted to ground for greater than 2 seconds.





1. CHECK FOR ACTIVE DTC
1. Turn the ignition on.
2. With the scan tool, read the active DTCs.

Does the scan tool display this DTC as active?

Yes

- Go To 2

No

- If the DTC is stored, check for an intermittent condition. Using the wiring diagram/schematic as a guide, visually inspect the related wiring harness connectors. Look for broken, bent, pushed out, or corroded terminals.
- Perform the BODY VERIFICATION TEST. Body Verification Test

2. POWERTRAIN CONTROL MODULE INTERNALLY SHORTED
1. Turn the ignition off.
2. Disconnect the Powertrain Control Module C1 harness connector.
3. Turn the ignition on.
4. With the scan tool, read DTCs.

Does the scan tool display this DTC as active?

Yes

- Go To 3

No

- Replace the Powertrain Control Module.
- Perform the BODY VERIFICATION TEST. Body Verification Test

3. (F1) FUSED IGNITION SWITCH OUTPUT (UNLOCK-RUN-START) CIRCUIT SHORT TO GROUND




1. Turn the ignition off.
2. Disconnect the IPM C5 harness connector.
3. Measure the resistance between ground and the (F1) Fused Ignition Switch Output (Unlock-Run-Start) circuit at the IPM C5 harness connector.

Is the resistance below 10K ohms?

Yes

- Repair the (F1) Fused Ignition Switch Output (Unlock-Run-Start) circuit for a short to ground.
- Perform the BODY VERIFICATION TEST. Body Verification Test

No

- Go To 4

4. CHECK FCM AND IPM FOR A SHORT TO GROUND
1. Disconnect the Front Control Module from the IPM.
2. Measure the resistance to ground at the male terminal of the IPM C5 connector.

Is the resistance below 10K ohms?

Yes

- Replace the IPM.
- Perform the BODY VERIFICATION TEST. Body Verification Test

No

- Replace the FCM.
- Perform the BODY VERIFICATION TEST. Body Verification Test