Power Sliding Door Module Left (PSDML)
B210E-BATTERY VOLTAGE HIGH
For a complete wiring diagram, refer to the Wiring Information. Electrical Diagrams
- When Monitored:
At all times.
- Set Condition:
When the Power Sliding Door Module detects input voltage above 16.5 volts for more than 15 seconds, this code will set.
1. CHECK ENGINE DTCs
NOTE: Ensure the battery is fully charged and serviceable before proceeding.
1. With the scan tool, read ENGINE DTCs
Are there any ENGINE DTCs present?
No
- Go To 2
Yes
- Diagnose and repair the DTC(s).
2. TEST FOR INTERMITTENT CONDITION
1. With the scan tool, record and erase DTCs
2. Start the engine and run for two minutes.
3. With the scan tool, read DTCs.
Does the scan tool display B210E-BATTERY VOLTAGE HIGH?
Yes
- Replace the Power Sliding Door Module.
- Perform the BODY VERIFICATION TEST. Body Verification Test.
No
- The conditions that caused this code to set are not present at this time. Using the wiring diagram/schematic as a guide, inspect the wiring and connectors.
- Perform the BODY VERIFICATION TEST. Body Verification Test.