Anti-Lock Brake System Module - Installation
INSTALLATION
CAUTION: When removing ABM from HCU, be sure to completely separate the two components (approximately 38 mm (1.5 in.) before removing ABM. Otherwise, damage to the pressure sensor or Pump Motor connection may result requiring HCU replacement. Do not to touch the sensor terminals on the HCU side or the contact pads on the ABM side as this may result in contamination and issues in the future.
NOTE: If the ABM is being replaced with a new ABM is must be reprogrammed with the use of a scan tool.
1. Install ABM to the HCU.
2. Install the pump connector to the ABM.
3. Install mounting bolts. Tighten to 2 Nm (16 in. lbs.).
4. Install the wiring harness connector to the ABM and push down on the release to secure the connector.
5. Install negative battery cable to the battery.
6. Connect the scan tool and initialize the ABM by performing the ABS Verification Test ABS Verification Test.