41E5
41E5-ABS/ESP CONTROL MODULE INTERNAL
For a complete wiring diagram Refer to the Wiring Information Electrical Diagrams.
- When Monitored:
Ignition on. The Anti-Lock Brake Module monitors its internal microprocessors for correct operation.
- Set Condition:
If the Anti-lock brake module detects an internal fault, the DTC is set.
ABM INTERNAL FAILURE DTC PRESENT
1. Turn the ignition on.
2. With the scan tool, read DTCs.
3. With the scan tool, erase DTCs.
4. Turn the ignition off.
5. Turn the ignition on.
6. With the scan tool, read DTCs.
Does the scan tool display ANTI-LOCK BRAKE MODULE INTERNAL FAILURE?
Yes
- Replace the Anti-Lock Brake Module.
- Perform ABS VERIFICATION TEST. ABS Verification Test.
No
- Refer to the ABS-INTERMITTENT CONDITION TEST. Testing and Inspection