AEC5
AEC5-OCCUPANT RESTRAINT CONTROLLER INTERNAL FAULT
Theory of Operation
When powered, the Occupant Restraint Controller (ORC) performs an internal self test. The repair of this fault condition does not involve any external circuitry and centers on verifying the integrity of the module's internal circuitry and software validity
- When Monitored:
With the ignition on.
- Set Condition:
The Occupant Restraint Controller (ORC) on board diagnostics continuously performs internal circuit tests. The ORC will set this DTC an out of range internal circuit identified.
Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. Restraints System Pre-Diagnostic Procedure
REPLACE THE ORC
NOTE: Ensure that the battery is fully charged.
Repair
- WARNING: If the Occupant Restraint Controller (ORC) is dropped at any time, it must be replaced. Failure to follow these instructions may result in possible serious or fatal injury.
WARNING: Turn the ignition off disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
- Replace the ORC.
- Perform the RESTRAINTS SYSTEM VERIFICATION TEST. Restraints System Verification Test