Occupant Restraint Controller (ORC)
B210D-BATTERY VOLTAGE LOW
Special Tools:
For a complete wiring diagram, refer to the Wiring Information.
Theory of Operation
The Occupant Restraint Controller module (ORC) receives power from both a fused run relay output and fused ignition switch output circuit from the Junction Block. These circuits power the ORC and the capacitors used to initiate the squib deployment circuits in the event of collision detection.
- When Monitored:
The Occupant Restraint Controller (ORC) module checks the (F929) Fused Ignition (Run Only) relay Output circuit and (F945) Fused Ignition Switch Output (Run-Start) circuit voltage input every 100ms throughout the ignition cycle.
- Set Condition:
The code will be set active if the ORC detects when both the Ignition (Run Only) and Ignition (Run-Start) supply circuits voltage is less than 9 volts for 15 seconds. The code will go from active to stored if the Ignition (Run Only) or Ignition (Run-Start) voltage is more than 9 volts for 5 seconds.
Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. Restraints System Pre-Diagnostic Procedure.
1. VERIFY THAT DTC B210D-BATTERY VOLTAGE LOW IS ACTIVE
NOTE: Make sure the battery is fully charged.
NOTE: Troubleshoot any PCM charging/cranking DTCs before proceeding.
1. Turn the ignition on, then off, then on again, wait 15 seconds.
2. With the scan tool, read the Occupant Restraint Controller (ORC) DTCs.
Does the scan tool display active: B210D-BATTERY VOLTAGE LOW?
Yes
- Go To 2
No
- Perform the RESTRAINTS SYSTEM INTERMITTENT TEST. . Restraints System Intermittent Condition Test
2. CHECK VOLTAGE OF ORC (F929) FUSED (RUN ONLY) RELAY OUTPUT AND (F945) FUSED IGNITION SWITCH OUTPUT (RUN-START) CIRCUITS
WARNING: Turn the ignition off disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
1. Disconnect the ORC harness connectors.
NOTE: Check the connectors - Clean and repair as necessary.
2. Connect the (8443-28) to the ORC harness connector.If the vehicle is equipped with the standard key ignition, follow this ignition on warning.
WARNING: Turn the ignition on, then reconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
If the vehicle is equipped with the keyless ignition, follow this ignition on warning.
WARNING: Disconnect the 12-volt battery wait two minutes before proceeding, remove the ORC fuses, connect the 12-volt battery, wait two minutes before proceeding. Cycle the ignition to the On position, then reconnect the ORC fuses. Wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
3. Measure the voltage between Ground and the (F945) Fused Ignition Switch Output (Run-Start) circuit at the (8443-28) cavity C2A-79.
4. Measure the voltage between Ground and the (F929) Fused (Run Only) Relay Output circuit at the (8443-28) cavity C2A-81.
Is the voltage above 10 volts on both circuits?
Yes
- WARNING: Turn the ignition off disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
- WARNING: If the Occupant Restraint Controller (ORC) is dropped at any time, it must be replaced. Failure to take the proper precautions can result in accidental airbag deployment. Failure to follow these instructions may result in possible serious or fatal injury.
- Replace the ORC. Occupant Restraint Controller - Removal.
- Perform the RESTRAINTS SYSTEM VERIFICATION TEST. Restraints System Verification Test.
No
- Repair the (F929) Fused (Run Only) Relay Output and/or (F945) Fused Ignition Switch Output (Run-Start) circuits for an open or high resistance.
- Perform the RESTRAINTS SYSTEM VERIFICATION TEST. Restraints System Verification Test.