Front Blower Motor Power Module - Installation
INSTALLATION
NOTE: LHD model shown. RHD model similar.
1. Position the blower motor power module (2) into the bottom of the HVAC housing (3).
2. Install the two screws (4) that secure the blower motor power module to the HVAC housing. Tighten the screws to 1.2 Nm (10 in. lbs.).
3. Connect the wire harness connector (1) to the blower motor power module.
4. Reconnect the negative battery cable.