Instrument Panel Center Bezel - Installation
INSTALLATION
CAUTION: Do not disconnect/connect the ICSS/switch bank without referring to the appropriate procedure. The harness connector is very fragile and could be damaged if not properly removed/installed.
1. Position the center bezel (1) in place and align the spring retainers with the instrument panel.
2. Connect the integrated center stack screen, . Integrated Center Stack Screen Module - Installation
3. Hand tap center bezel (1) in place ensuring proper seat.
4. Install the fasteners (2) securing the bezel (1) to the I/P. Tighten the fasteners securely.
CAUTION: Do not disconnect/connect the ICSS/switch bank without referring to the appropriate procedure. The harness connector is very fragile and could be damaged if not properly removed/installed.
5. Position the switch-bank assembly in place.
6. Connect the electrical connector (2) to the back of the switch-bank assembly (1), Instrument Cluster Switch Pod - Installation
7. Position the switch-bank in the I/P and press evenly the engage the two lower clips (3).
8. Install, and tighten the two screws (2) that secure the switch-bank (1) to the I/P (4).
9. Install the instrument panel outlet vent/trim (1), Air Outlet - Installation.
10. Align and press firmly to install the instrument panel trim (1) located left of the center stack bezel.
11. Install the glove box.
12. Connect the negative battery cable.