B16A8
B16A8-HIGH BEAM CAMERA ALIGNMENT PERFORMANCE - RIGHT
For a complete wiring diagram, refer to the Wiring Information.
- When Monitored:
With the ignition on.
- Set Condition:
The DTC will be set if the target light source is not within the correctable limits of the mirror.
Diagnostic Test
CHECK FOR AN ACTIVE DIAGNOSTIC TROUBLE CODE (DTC)
1. With the scan tool, read DTCs.
Does the scan tool display this DTC as active?
Yes
- Perform the Smart Beam Calibration. Adjustments.
No
- Test complete.