With Malfunction Indicator Light (MIL)
NOTE: It may be necessary to service non-EEC-IV faults before running the quick test.Continuous codes recorded in this step will be used for diagnosis in CONTINUOUS MEMORY CODES after a pass code is received in both Key On Engine Off (KOEO) and Engine Running (ER) self-tests.
Deviation from this procedure may cause false codes to be output.
1. START engine and bring to normal operating temperature.
NOTE: If engine will not start or stalls after starting, proceed with the Key On Engine Off (KOEO) self test.
2. Turn the key OFF, then wait ten seconds.
Jumper Wire Installed Between Pin #2 And Self Test Input (STI):
NOTE: For remainder of the test procedure depress the accelerator pedal.
3. ACTIVATE the self test by grounding the STI connector.
4. Turn the ignition key to the ON position.
5. Record all codes received.
6. Turn the ignition key OFF and DEACTIVATE the self test.
7. If a pass code (11 or 111) is received for hard codes (11/111-10-any code), proceed with next test step. Key ON Engine Running (KOER) Self-Test
If any hard codes are received, refer to the appropriate service code chart for diagnostic path. Manufacturer Code Charts
If no codes are received, go to pinpoint test QA, step QA1. QA1 - Check VREF Voltage At Self-Test Connector
After completing the proper pinpoint test(s), return to this test and perform the KOEO test again.