KD10 - Check CANP Circuit For Short to Power
- Key "OFF".
- Canister Purge (CANP) solenoid disconnected.
- Breakout box installed, Powertrain Control Module (PCM) disconnected.
- Scan Tool disconnected from Data Link connector.
- Measure resistance between test pin 11, 15, 31 or 54 (refer to Testing Schematic) and test pins 37 and 57 at the breakout box. KD - Testing Schematic
- Is each resistance greater than 10,000 ohms?
Yes -- Replace PCM. Remove breakout box and Scan Tool. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)
No -- Service short to power. Remove breakout box and Scan Tool. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)