Disassembly and Assembly
REMOVAL1. Remove the Intake Manifold Runner Control (IMRC) vacuum actuators.
1 Disconnect the electrical connectors.
2 Disconnect the vacuum hoses.
3 Remove the bolts from each bracket.
4 Disconnect the two linkages.
2. Remove the IMRC vacuum actuators.
INSTALLATION
NOTE: If the IMRC runners require service, the entire lower intake manifold must be replaced.
1. Position the IMRC vacuum actuators for installation.
NOTE: Each time the IMRC vacuum actuator vacuum rod is removed and installed, a new nylon bushing must be installed.
2. Install the rod linkages.
3. Install and tighten the bolts.
4. Connect the vacuum hoses and electrical connectors.