Flow of Diagnosis
1. Verify the customer concern by operating the backup lamps.2. Visually inspect for obvious signs of mechanical and electrical damage:
VISUAL INSPECTION CHART
Mechanical
^ Damaged backup lamp switch
Electrical
^ Blown fuse(s)
^ Damaged wiring harness
^ Loose or corroded connections
^ Damaged backup lamp
^ Damaged Digital Transmission Range (DTR) sensor
3. If the concern is not visually evident, determine the symptom and proceed to Symptom Chart. Symptom Related Diagnostic Procedures