Operation CHARM: Car repair manuals for everyone.

Component Tests and General Diagnostics

Terminals:






MICRO ISO RELAY
Use 73 Digital Multimeter to check for continuity between terminal 2 and all other terminals. If resistance is 5 ohms or less between terminal 2 and any other terminal, replace the relay. If resistance is greater than 5 ohms, continue the test. Use two jumper wires to connect relay terminals 1 and 3 directly to the positive battery terminal. Set 73 Digital Multimeter in volts position and check for voltage at terminal 4. If battery voltage is not indicated, replace the relay. If battery voltage is indicated, connect a third jumper wire to terminal 2, and ground the jumper wire to a known good ground. Check for voltage at terminal 5. If battery voltage is not indicated, replace the relay.