Lifter / Lash Adjuster, Valve

GENERAL SPECIFICATIONS
Tappet Diameter 22.2-22.212 mm (0.8740-0.8745 inch)
Tappet to Bore Clearance 0.018-0.069 mm (0.0007-0.0027 inch)
Service Limit 0.127 mm (0.005 inch)
Hydraulic Lifter Leakdown Rate for 1/16 in Travel 10-50 seconds
Collapsed Tappet Gap Allowable 1.803-4.343 mm (0.071-0.171 inch)
Collapsed Tappet Gap Desired 2.311-3.385 mm (0.091-0.151 inch)

TORQUE SPECIFICATIONS
Valve Tappet Guide Plate Retainer Bolts 8-12 Nm (71-106 in. lbs.)