Compressor HVAC: Service Precautions
CAUTION: When replacing an A/C compressor which has failed internally, perform the following procedures to prevent contamination of the refrigerant system.^ If A/C flusher is available, perform the Flushing procedure.
^ If A/C flusher is not available, perform the Refrigerant System Filtering after A/C Compressor Replacement procedure.
^ Replace the suction accumulator/drier; refer to Accumulator, Air Conditioning.
^ Replace the A/C evaporator core orifice; refer to Expansion Tube, A/C.