Lifter / Lash Adjuster, Valve
Tappet diameter | 0.8740 - 0.8745 Inch (in) |
Tappet to bore clearance | 0.0007 - 0.0027 Inch (in) |
Service limit | 0.005 Inch (in) |
Hydraulic lifter Leakdown rate for 1/16 in travel | 10 - 50 Second (sec) |
Collapsed tappet gap allowable | 0.071 - 0.171 Inch (in) |
Collapsed tappet gap desired | 0.091 - 0.151 Inch (in) |
Valve tappet guide plate retainer bolts | 71-106 Inch Pound-Force (in.lb) |