Air Flow Meter/Sensor: Service and Repair
REMOVAL1. Loosen the air inlet tube clamps.
2. Disconnect the three vacuum lines and remove the air inlet tube.
^ PCV closeout
^ IAB hose
^ Supercharger vacuum actuator vacuum line
3. Remove the Mass Air Flow (MAF) sensor.
1 Disconnect the electrical connector.
2 Remove the four screws.
3 Remove the MAF sensor.
INSTALLATION
1. To install, reverse the removal procedure.