Operation CHARM: Car repair manuals for everyone.

95 and 130 Ampere

REMOVAL
1. Disconnect the battery cables.
2. Remove the air cleaner assembly.
3. Remove the drive belt from the Generator (GEN).







4. Disconnect the generator rear connections.
1 Remove the B+ terminal nut and disconnect the terminal.
2 Disconnect the S electrical connector.
3 Disconnect the ASI electrical connector.







5. Remove the bolts and lift out the generator.

INSTALLATION












1. Follow the removal procedure in reverse order.