Test G
G1:
G2:
G3:
G4:
G4 - G5:
Normal Operation
The Restraints Control Module (RCM) monitors the circuit to the driver safety belt pretensioner. When the RCM detects a circuit short to ground it will set Lamp Fault Code (LFC) 17 and Diagnostic Test Code (DTC) B1879.
Possible Causes
A short to ground on the driver safety belt pretensioner circuit can be caused by:
^ a short to ground on circuit 1079 (LG/RD).
^ a short to ground on circuit 1080 (LG/BK).
^ a short to ground on the driver safety belt pretensioner.
^ an RCM internal concern.