Operation CHARM: Car repair manuals for everyone.

Fill

Fill

1. WARNING: Do not mix oil types, any mixture or any unapproved oil could lead to seal deterioration and leaks. A leak could ultimately cause loss of fluid, which could result in a loss of power steering assist.





Fill the reservoir.
^ Use Motorcraft MERCON (R) Multi-Purpose ATF XT-2-QDX or equivalent meeting Ford Specification MERCON (R).





2. Remove the ignition coil fuse to disable the vehicle.
3. Raise the front wheels off the floor.

4. CAUTION: Do not crank the engine for more than 15 seconds at a time. Allow the starter to cool for 1 minute before cranking again. Premature starter failure can occur.

CAUTION: Do not hold the steering wheel against the stops for more than three to five seconds at a time. Damage to the power steering pump could occur.





Turn the steering wheel from stop-to-stop while cranking the engine.
5. Lower the vehicle.

6. CAUTION: Do not overfill the reservoir.





Fill the reservoir.
^ Use Motorcraft MERCON (R) Multi-Purpose ATF XI-2-QDX or equivalent meeting Ford Specification MERCON (R).





7. Install the ignition coil fuse.