Transfer Case Draining and Filling
Transfer Case Draining and Filling1. Position a suitable container under the transfer case.
2. Remove the drain plug and drain the transfer case.
3. CAUTION: If the correct fill procedures are not followed, a transfer case failure can result.
NOTE: Fluid level must be just below the fill plug.
Remove the fill plug from the rear of the transfer case and check the fluid level.
^ If the fluid is below the level, fill with Motorcraft MERCON Multi-Purpose Automatic Transmission Fluid XT-2-QDX or MERCON equivalent.
4. CAUTION: Do not use air tools.
Tighten the drain and fill plugs.